Product Introduction
The fully automatic water softener can be divided into various series such as time control type, flow control type, and continuous supply water softening system type. There are corresponding equipment for 2T/H-1800T/H effluent, and different requirements for softened water equipment can be customized according to the needs of different enterprises. Can be equipped with automatic agitator with solution tank, online hardness monitoring instrument, online flow meter and other equipment, with water quality hardness ≤ 0.03mmol/L.
Process Selection
1.Low hardness and small water volume of raw water
Single stage sodium ion exchange softening
Applicable: Small scale water supply, boiler makeup water, air conditioning circulating water
2. Raw water has high hardness and requires extremely soft effluent
Double stage series sodium ion softening
Applicable: High pressure boilers, precision cooling systems
3. Raw water has high alkalinity and is prone to scaling
Softening+alkali removal process (hydrogen sodium series/weak acid cation exchange)
Applicable: high alkalinity groundwater, industrial circulating water
4. Continuous high flow water supply
Multi tank parallel+continuous operation process
Applicable: Water plants, large factories, centralized water supply
5. Prioritize water conservation and minimize regenerated wastewater
Reverse flow regeneration/frequency conversion softening process
The water utilization rate can reach over 95%
Equipment Selection
1. Tank form
Vertical tank: small footprint, easy installation, most commonly used
Horizontal tank: high flow, height restricted scenarios
Fiberglass/Carbon Steel Lining/Stainless Steel: Choose according to the corrosiveness of water quality
2. Control mode
Time type: Fixed cycle regeneration, suitable for stable water flow
Flow type: regenerated according to water consumption, more salt efficient and intelligent
Fully automatic: No need for duty, automatic backwashing, salt absorption, replacement, and forward washing
3. Resin selection
Standard: 001 × 7 strong acidic cation exchange resin
High salt/high hardness: Choose macroporous and anti pollution resin
4. Flow and specification selection
Select tank diameter based on hourly water consumption Q (m³/h)
Typical filtration speed: 15-25 m/h
Resin layer height: 800-1200mm